• Cardiac Markers Combo Test Ck-MB Myoglobin Troponin I Rapid Test
  • Cardiac Markers Combo Test Ck-MB Myoglobin Troponin I Rapid Test
  • Cardiac Markers Combo Test Ck-MB Myoglobin Troponin I Rapid Test
  • Cardiac Markers Combo Test Ck-MB Myoglobin Troponin I Rapid Test
  • Cardiac Markers Combo Test Ck-MB Myoglobin Troponin I Rapid Test
  • Cardiac Markers Combo Test Ck-MB Myoglobin Troponin I Rapid Test

Cardiac Markers Combo Test Ck-MB Myoglobin Troponin I Rapid Test

Type: IVD Reagent
Certificate: ISO, CE
Shelf Life: 24 Months
Usage: Professional Use
Sample: Whole Blood, Serum, Plasma
Result Time: Within 15 Mins
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Intended Use
  • Introduction
  • Contents
  • Storage & Statibility
  • Sample Collection&Storage
  • Operation
  • Detailed Photos
  • Company Profile
Overview

Basic Info.

Model NO.
CMC-DW32
Principle
Immunochromatography
Storage
2~30ºC
Transport Package
Cartons
Specification
25test/box
Trademark
Dewei
Origin
China
Production Capacity
100, 000PCS/Day

Product Description

Intended Use


The Cardiac Markers 3 in 1 Rapid Test Combo is a rapid visual immunoassay for the qualitative presumptive detection of human Myoglobin, CK-MB and cardiac Troponin I in whole blood, serum or plasma. This kit is intended for use as an aid in the diagnosis of  myocardial infarction (MI).

Introduction

 

Myoglobin (MYO), Creatine Kinase MB (CK-MB) and cardiac Troponin I (cTnI) are proteins released into the bloodstream after cardiac injury. Myoglobin is a heme-protein normally found in skeletal and cardiac muscle with a molecular weight of 17.8 kDa. It constitutes about 2 percent of total muscle protein and is responsible for transporting oxygen within muscle cells. When muscle cells are damaged, Myoglobin is released into the blood rapidly due to its relatively small size. The level of Myoglobin increases measurably above baseline within 2-4 hours post-infarct, peaking at 9-12 hours, and returning to baseline within 24-36 hours. CK-MB is an enzyme also present in the cardiac muscle, with a molecular weight of 87.0 kDa. Creatine Kinase is a dimeric molecule formed from two subunits designated as "M" and "B", which combine to form three different isoenzymes, CK-MM, CK-BB and CK-MB. CK-MB is the isoenzyme of Creatine Kinase most involved in the metabolism of cardiac muscle tissue. The release of CK-MB into the blood following an MI can be detected within 3-8 hours after the onset of symptoms. It peaks within 9 to 30 hours, and returns to baseline levels within 48 to 72 hours. Cardiac Troponin I is a protein found in cardiac muscle, with a molecular weight of 22.5 kDa. Troponin I is part of a three subunit complex comprised of Troponin T and Troponin C. Along with tropomyosin, this structural complex forms the main component that regulates the calcium sensitive ATPase activity of actomyosin in striated skeletal and cardiac muscle. After cardiac injury occurs, Troponin I is released into the blood 4-6 hours after the onset of pain. The release pattern of Troponin I is similar to CK-MB, but while CK-MB levels return to normal after 72 hours, Troponin I remains elevated for 6-10 days, thus providing for a longer window of detection for cardiac injury.

 

Contents

 
•Rapid test cassette with desiccant
• Buffer
• Disposable pipettes
• Package insert
 

Storage & Statibility

 
• Store at 2 ~ 30 º C in the sealed pouch for 24 months.
• Keep away from direct sunlight, moisture and heat.
• DO NOT FREEZE.

Sample Collection&Storage

 
• Cardiac Markers 3 in 1 Rapid Test Combo is intended for use with human whole blood, serum, or plasma specimens only.
 
• Only clear, non-hemolyzed specimens are recommended for use with this test. Serum or plasma should be separated as soon as possible to avoid hemolysis.
 
• Perform testing immediately after specimen collection. Do not leave specimens at room temperature for prolonged periods. Serum and plasma specimens may be stored at 2-8°C for up to 3 days. For long term storage, specimens should be kept below -20°C. Whole blood collected by venipuncture should be stored at 2-8°C if the test is to be run within 2 days of collection. Do not freeze whole blood specimens. Whole blood collected by fingerstick should be tested immediately.
 
• Containers containing anticoagulants such as EDTA, citrate, or heparin should be used for whole blood storage.
 
• Bring specimens to room temperature prior to testing. Frozen specimens must be completely thawed and mixed well prior to testing. Avoid repeated freezing and thawing of specimens.
 
• If specimens are to be shipped, pack them in compliance with all applicable regulations for transportation of etiological agents.
 
• Icteric, lipemic, hemolysed, heat treated and contaminated specimens may cause erroneous results.
 
There is a slight possibility that some whole blood specimens with very high viscosity or which have been stored for more than 2 days may not run properly on the test device. Repeat the test with a serum or plasma specimen from the same patient using a new test device.

Operation



Bring tests, specimens, buffer and/or controls to room temperature (15- 30°C) before use.
1. Remove the test from its sealed pouch and use it as soon as possible. For best results, the assay should be performed within one hour.
 
2. Place the test device on a clean and level surface. For Serum or Plasma specimens: Hold the dropper vertically and transfer 2 drops of serum or plasma (approximately 50 μL) to
the specimen well (S) of the test device, then start the timer. See illustration below. Hold the strip by the end, where the product name is printed. To avoid contamination, do not touch the strip membrane.
OR
For Whole blood specimens: Transfer 3 drops of whole blood specimen (approximately 75 µL) to the specimen well of the device with the provided disposable pipette, then add 1 drop of buffer and start the timer.
OR
For Fingerstick whole blood specimens: Allow 3 hanging drops of fingerstick whole blood specimen to fall into the center of the specimen well (S) on the device, then add 1 drop of buffer and start the timer.
Avoid trapping air bubbles in the specimen well (S), and do not add any solution to the result area.
As the test begins to work, color will migrate across the membrane.

 
3. Wait for the colored band(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.


 

Detailed Photos

Cardiac Markers Combo Test Ck-MB Myoglobin Troponin I Rapid Test
Cardiac Markers Combo Test Ck-MB Myoglobin Troponin I Rapid Test

 

Company Profile

About Us

Cardiac Markers Combo Test Ck-MB Myoglobin Troponin I Rapid TestDewei Medical Equipment Co., Ltd. is a high-tech enterprise specialized in developing and marketing of Medical Consmuables like Clinical Laboratory analyzer and reagents, Hematology Analyzer and Reagents, Washing Solutions, Urine Sediment Reagents and DNA/RNA Preservation Kits.
During the special period, Dewei also develop the reagent kits, like Virus Transport Medium with swab, Rapid test and Saliva Collection Kits.
Dewei products are widely used in hospital clinics, disease control centers, blood banks, veterinary clinics, scientific research center and college laboratories.

 

R&D team
15% annual sales amount is devoted R&D department.
With professional R&D team, Dewei is continuously making new achievements on innovation, gaining numbers of national invention patents and professional technical awards. Meanwhile, Dewei focuses on the improvement of technology to guarantee product quality and pursue product performance.
Cardiac Markers Combo Test Ck-MB Myoglobin Troponin I Rapid Test


Certificate
Cardiac Markers Combo Test Ck-MB Myoglobin Troponin I Rapid Test


Production Workshop

Cardiac Markers Combo Test Ck-MB Myoglobin Troponin I Rapid Test


Exhibition

Cardiac Markers Combo Test Ck-MB Myoglobin Troponin I Rapid Test

Our Team
Cardiac Markers Combo Test Ck-MB Myoglobin Troponin I Rapid Test
Cardiac Markers Combo Test Ck-MB Myoglobin Troponin I Rapid Test
 

Transportation
Cardiac Markers Combo Test Ck-MB Myoglobin Troponin I Rapid Test
Cardiac Markers Combo Test Ck-MB Myoglobin Troponin I Rapid Test

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
50
Year of Establishment
2020-08-03