Prostate Specific Antigen (PSA) for Whole Blood Serum Plasma Rapid Test

Product Details
Customization: Available
Type: IVD Reagent
Certificate: ISO
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
50
Year of Establishment
2020-08-03
  • Prostate Specific Antigen (PSA) for Whole Blood Serum Plasma Rapid Test
  • Prostate Specific Antigen (PSA) for Whole Blood Serum Plasma Rapid Test
  • Prostate Specific Antigen (PSA) for Whole Blood Serum Plasma Rapid Test
  • Prostate Specific Antigen (PSA) for Whole Blood Serum Plasma Rapid Test
  • Prostate Specific Antigen (PSA) for Whole Blood Serum Plasma Rapid Test
  • Prostate Specific Antigen (PSA) for Whole Blood Serum Plasma Rapid Test
Find Similar Products
  • Overview
  • Intended Use
  • Introduction
  • Contents
  • Storage & Statibility
  • Sample Collection&Storage
  • Operation
  • Detailed Photos
  • Company Profile
Overview

Basic Info.

Model NO.
PSA-DW02
Shelf Life
24 Months
Usage
Professional Use
Sample
Whole Blood, Serum, Plasma
Result Time
Within 15 Mins
Principle
Immunochromatography
Storage
2~30ºC
Transport Package
Cartons
Specification
40test/box
Trademark
Dewei
Origin
China
Production Capacity
100, 000PCS/Day

Product Description

Intended Use


The Prostate Specific Antigen (PSA) is a rapid visual immunoassay for the qualitative presumptive detection of prostate specific antigens in human whole blood, serum, or plasma specimens. This kit is intended for use as an aid in the diagnosis of prostate cancer.

Introduction


Prostate cancer is the most frequent type of cancer found in the man and the second cause of death due to the cancer in man. Prostate cancer incidences increase dramatically in males with an age over 40 years, occurring in 50% of those over 70 years. Compared to other cancers, prostate cancer is more successfully treated if diagnosed early. Recently, another prostate enzyme has been identified and purified, which specific for prostate tissue, normal or malignant, and also found in periurethral glands. This enzyme is called prostate specific antigen (PSA). Looking at PSA from the biological side, it is a 33 kDa protein that is synthesized in the prostatic gland. It functions as a serine protease and serves to liquefy the seminal fluid. As demonstrated by immunohistological studies, PSA is localized in the cytoplasm of prostate acinar cells, ductal epithelium and in the secretion on the ductal lumina, present in normal, benign hyperplastic and malignant prostate tissues as well as in metastatic prostate cancer and in seminal fluid. An elevation of the serum concentration is reported in patients with both benign prostatic hypertrophy prostate carcinoma, but rarely in healthy men and is absent in normal women. PSA is not present in any other normal tissue obtained from men, nor is it produced by cancers of the breast, lung, colon, rectum, stomach, pancreas and thyroid. The PSA level in serum or plasma of normal health men should be lower than 4 ng/ml, so the reference line is designed to be approximately the intensity of 4 ng/ml. If the structural integrity of the prostate is disturbed and/or the gland size is increased, the amount of PSA in the blood serum/plasma may become elevated, reaching levels up to 200 ng/ml PSA. At a cut-off of 4 ng/ml PSA, further medical analysis is recommended, although at a concentration range between 4-10 ng/ml PSA the elevated levels are commonly not caused by cancer but by other factors like benign prostatic hyperplasia or prostatitis. Plasma concentrations of >10 ng/ml PSA strongly indicate the presence of prostatic carcinoma. Although a race- and/or age-dependent modification of the cut-off has been discussed in the literature, the amount of 4 ng/ml PSA is the generally accepted value at which follow-up examinations of the patient should be started.
 

Contents

 
• Rapid test cassette with desiccant.
• Buffer
• Pipette
• Package insert
 

Storage & Statibility

 
• Store at 2 ~ 30 º C in the sealed pouch for 24 months.
• Keep away from direct sunlight, moisture and heat.
• DO NOT FREEZE.
 

Sample Collection&Storage


• The PSA Rapid Test is intended for use with human whole blood, serum, or plasma specimens only.
• Intake of Finasteride (5-reductaseinhibitor) will reduce the PSA concentration by max. 50%. This should be considered by the interpretation of the results.
• Different factors could increase the PSA level in blood serum and should be avoided before collection of the blood sample and/or should be desisted from by the patient before sample taking.
• Ride on a bicycle: 24 hours before taking of blood sample
• Sexual activities (Ejaculation): 24-48 hours before taking of blood sample
• Every manipulation of the prostate by medical examinations. The following intervals are recommended until taking of blood sample:
Examination Interval
Prostatic biopsy
> 6 weeks
Transurethal resection of the prostate
> 6 weeks
Transrectal prostatic ultrasound
> 1 week
Rigid Cytoscopy
> 1 week
Digital rectal examination
3 days - 1 week
Prostatic massage
> 1 week
 
Only clear, non-hemolyzed specimens are recommended for use with thistest. Serum or plasma should be separated assoon as possible to avoid hemolysis.
Perform testing immediately after specimen collection. Do not leave specimens at room temperature for prolonged periods. Serum and plasma specimens may be stored at 2-8°C for up to 3 days. For long term storage, specimens should be kept below -20°C. Whole blood collected by venipuncture should be stored at 2-8°C if the test is to be run within 2 days of collection. Do not freeze whole blood specimens. Whole blood collected by fingerstick should be tested immediately.
Containers containing anticoagulants such as EDTA, citrate, or heparin should be used for whole blood storage.
Bring specimens to room temperature prior to testing. Frozen specimens must be completely thawed and mixed well prior to testing. Avoid repeated freezing and thawing of specimens.
If specimens are to be shipped, pack them in compliance with all applicable regulations for transportation of etiological agents.
Icteric, lipemic, hemolysed, heat treated and contaminated specimens may cause erroneous results.
 

Operation


Bring tests, specimens, buffer and/or controls to room temperature (15- 30°C) before use.
1. Remove the test from its sealed pouch, and place it on a clean, level surface. Label the device with patient or control identification. For best results, the assay should be performed within one hour.
2. Transfer 1 drops of serum/plasma to the specimen well (S) of the device with the provided disposable pipette, then add 1 drop of buffer, and start the timer.
OR
Transfer 2 drops of whole blood to the specimen well (S) of the device with the provided disposable pipette, then add 1 drop of buffer, and start the timer.
OR
Allow 2 hanging drops of fingerstick whole blood to fall into the center of the specimen well (S) of the test device, then add 1 drop of buffer, and start the timer.
Avoid trapping air bubbles in the specimen well (S), and do not add any solution to the result area.
As the test begins to work, color will migrate across the membrane.
3. Wait for the colored band(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.

Detailed Photos

Prostate Specific Antigen (PSA) for Whole Blood Serum Plasma Rapid Test
Prostate Specific Antigen (PSA) for Whole Blood Serum Plasma Rapid Test

 

Company Profile

About Us

Prostate Specific Antigen (PSA) for Whole Blood Serum Plasma Rapid TestDewei Medical Equipment Co., Ltd. is a high-tech enterprise specialized in developing and marketing of Medical Consmuables like Clinical Laboratory analyzer and reagents, Hematology Analyzer and Reagents, Washing Solutions, Urine Sediment Reagents and DNA/RNA Preservation Kits.
During the special period, Dewei also develop the reagent kits, like Virus Transport Medium with swab, Rapid test and Saliva Collection Kits.
Dewei products are widely used in hospital clinics, disease control centers, blood banks, veterinary clinics, scientific research center and college laboratories.

 

R&D team
15% annual sales amount is devoted R&D department.
With professional R&D team, Dewei is continuously making new achievements on innovation, gaining numbers of national invention patents and professional technical awards. Meanwhile, Dewei focuses on the improvement of technology to guarantee product quality and pursue product performance.
Prostate Specific Antigen (PSA) for Whole Blood Serum Plasma Rapid Test


Certificate
Prostate Specific Antigen (PSA) for Whole Blood Serum Plasma Rapid Test


Production Workshop

Prostate Specific Antigen (PSA) for Whole Blood Serum Plasma Rapid Test


Exhibition
Prostate Specific Antigen (PSA) for Whole Blood Serum Plasma Rapid Test

Our Team

Prostate Specific Antigen (PSA) for Whole Blood Serum Plasma Rapid Test
Prostate Specific Antigen (PSA) for Whole Blood Serum Plasma Rapid Test
 

Transportation
Prostate Specific Antigen (PSA) for Whole Blood Serum Plasma Rapid Test
Prostate Specific Antigen (PSA) for Whole Blood Serum Plasma Rapid Test

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier