New Tech Zika Ns1 Antigen Rapid Test Spread by Daytimeactive Aedes Mosquitoes

Product Details
Customization: Available
Certification: CE, MSDS, ISO13485
Component: Rapid Test + Buffer + Pipettes
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
50
Year of Establishment
2020-08-03
  • New Tech Zika Ns1 Antigen Rapid Test Spread by Daytimeactive Aedes Mosquitoes
  • New Tech Zika Ns1 Antigen Rapid Test Spread by Daytimeactive Aedes Mosquitoes
  • New Tech Zika Ns1 Antigen Rapid Test Spread by Daytimeactive Aedes Mosquitoes
  • New Tech Zika Ns1 Antigen Rapid Test Spread by Daytimeactive Aedes Mosquitoes
  • New Tech Zika Ns1 Antigen Rapid Test Spread by Daytimeactive Aedes Mosquitoes
  • New Tech Zika Ns1 Antigen Rapid Test Spread by Daytimeactive Aedes Mosquitoes
Find Similar Products

Basic Info.

Model NO.
ZIKA
Specimen
Whole Blood, Serum, Plasma
Result Time
Within 15 Mins
Storage
2~30°c
Principle
Immunochromatography
Shelf Life
24 Months
Certificate
CE
Usage
Professional Used
Transport Package
40tests/Box; 25tests/Box
Specification
1000tests/Carton
Trademark
Dewei
Origin
China

Product Description


INTENDED USE

The Zika NS1 Rapid Test is a rapid chromatographic immunoassay for the qualitative detection of NS1 antigen of Zika virus in human whole blood, serum, or plasma as an aid in the diagnosis of Zika infections.
We have Zika IgG/IgM antobody test too if you need.

 
Storage 2~30 º C
Specimen Whole Blood/Serum/Plasma
Component Rapid Test + Buffer + Pipettes
Principle Colloidal gold rapid tests
Reading  Within 15mins
Package 40tests/box; 25tests/box
Trademark Dewei
Origin China

WARNINGS AND PRECAUTIONS
Immunoassay for in vitro diagnostic use only.
Do not use after expiration date.
The test should remain in the sealed pouch until use.
The used test should be discarded according to local regulations.

STORAGE AND STABILITY
The kit should be stored at 2-30°C until the expiry date printed on the sealed pouch.
The test must remain in the sealed pouch until use.
Keep away from direct sunlight, moisture and heat.
Do not freeze.
Care should be taken to protect the components of the kit from contamination. Do not use if there is evidence of microbial contamination or precipitation. Biological contamination of dispensing equipment, containers or reagents can lead to false results. 

OPERATION
Bring tests, specimens, buffer and/or controls to room temperature (15-30°C) before use.
1. Remove the test from its sealed pouch, and place it on a clean, level surface. Label the device with patient or control identification. For best results, the assay should be performed within one hour.
2. Transfer 2 drops of serum/plasma (approximately 75 µL) to the specimen well (S) of the device with the provided disposable pipette, then add 1 drop of buffer, and start the timer.
Allow 3 drops of whole blood (approximately 50 µL) to fall into the center of the specimen well(s) of the test cassette, then add 1 drop of buffer, and start the timer.
Avoid trapping air bubbles in the specimen well (S), and do not add any solution to the result area.
As the test begins to work, color will migrate across the membrane.
3. 
Wait for the colored band(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.
 
INTERPRETATION OF RESULTS
Preliminary positive (+)Only one colored band appears, in the control region (C). No colored band appears in the test region (T).Negative (-)Two colored bands appear on the membrane. One band appears in the control region (C) and another band appears in the test region (T).InvalidControl band fails to appear. Results from any test which has not produced a control band at the specified read time must be discarded. Please review the procedure and repeat with a new test. If the problem persists, discontinue using the kit immediately and contact your local distributor.


PRODUCT IMAGES 

New Tech Zika Ns1 Antigen Rapid Test Spread by Daytimeactive Aedes Mosquitoes
New Tech Zika Ns1 Antigen Rapid Test Spread by Daytimeactive Aedes Mosquitoes

R&D TEAM

New Tech Zika Ns1 Antigen Rapid Test Spread by Daytimeactive Aedes Mosquitoes
New Tech Zika Ns1 Antigen Rapid Test Spread by Daytimeactive Aedes Mosquitoes


PRODUCTION LINE

New Tech Zika Ns1 Antigen Rapid Test Spread by Daytimeactive Aedes Mosquitoes
New Tech Zika Ns1 Antigen Rapid Test Spread by Daytimeactive Aedes Mosquitoes
New Tech Zika Ns1 Antigen Rapid Test Spread by Daytimeactive Aedes Mosquitoes


OFFICES

New Tech Zika Ns1 Antigen Rapid Test Spread by Daytimeactive Aedes Mosquitoes
New Tech Zika Ns1 Antigen Rapid Test Spread by Daytimeactive Aedes Mosquitoes
New Tech Zika Ns1 Antigen Rapid Test Spread by Daytimeactive Aedes Mosquitoes


EXHIBITIONS 

New Tech Zika Ns1 Antigen Rapid Test Spread by Daytimeactive Aedes Mosquitoes
New Tech Zika Ns1 Antigen Rapid Test Spread by Daytimeactive Aedes Mosquitoes
New Tech Zika Ns1 Antigen Rapid Test Spread by Daytimeactive Aedes Mosquitoes


SHIPMENTS 

New Tech Zika Ns1 Antigen Rapid Test Spread by Daytimeactive Aedes Mosquitoes
New Tech Zika Ns1 Antigen Rapid Test Spread by Daytimeactive Aedes Mosquitoes
New Tech Zika Ns1 Antigen Rapid Test Spread by Daytimeactive Aedes Mosquitoes

 

Any more rapid tests you need, welcome leave us message or send email!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier